VolAmp Ltd VES 8034 Hub VolAmp Ltd

 

VES 8034

FIBRE OPTIC / AUI / BNC HUB

( Obsolete )

  • Fibre Optic, BNC and AUI ports.
  • Compact size
  • 2km Fibre Optic link
  • Low cost
  • Traffic indicators
  • Fibre Optic link status indication

TECHNICAL DESCRIPTION :

The VES 8034 Fibre Optic / AUI / THINNET Repeater uses the latest technology to provide an economical solution for the of an Ethernet segment or fibre link to an AUI interface

The Fibre link conforms to the Fibre Optic Inter Repeater Link standard ensuring compatibility with any other device operating to this standard. The fibre links may be up to 2km and be of fibre diameter from 50/125 to 100/140.
The repeater performs all the functions expected on an IEEE 802.3 Repeater:
Preamble reconstitution , Partition recovery on segment fault correction
Data retiming , Auto – partitioning on segment fault.
Fragment extensions
The unit is designed for optimum power efficiency and does not require assisted cooling, this coupled with its compactness allows the unit to be easily mounted on walls using VolAmp wall mounting brackets BRKT-1. The isolation and immunity provided by Fibre Optic Repeaters is such that it is common practice to isolate buildings via Fibre Optic cables and Repeaters thus avoiding earth loop effects and the hazards of lighting strikes etc.

The Following VolAmp Transceivers are compatible with the 802.3 standards:
THICK COAX (bee sting) -VES 8005-1 THIN COAX (BNC) – VES 8051A
THICK COAX (N type) – VES 8055-2 FIBRE OPTIC -VES 8000P
UTP -VES 8057S

SPECIFICATION :

IEEE 802.3 for AUI, For Thinnet interface and for Fibre Optic repeater link.
Optical Spec: Receiver sensitivity – Mean Optical power better than – 30 dBm for 10 BER
Transmitter power - Mean Optical power better than – 12 into 62.5/125 fibre of 0.275 NA.

Indicators: - POWER – Power mains connected
BNC- Activity on Thinnet
COL - Collision
AUI – Activity on AUI link
F.O – Activity on fibre optic link
RX LOSS – Fibre optic RX loss

Mechanical case :- Totally enclosed metal construction
Signal connections :- 1x 15 way D- Connector for AUI Connector.
2 x ST Fibre Optic Connectors or 2 x SMA Fibre Optic Connectors
Electrical :- Power inlet IEC 320 ,Mains 198 – 264 VAC for 50 – 60 Hz at 10 VA , Fuse protection: 125mA
Environment :- Operating temperature: 0oC to 45oC Storage temperature: -20oC to 70oC
Humidity:- 10% to 90% non-condensing
Dimensions :- 245mm x 185mm x 46mm(overall) : 245mm x 168.5mm x 40mm (body)Weight: 1.125kg

Order Code. Description .
VES 8034/ST
. . . . . . . . . . . . . . . .Fibre Optic / AUI / BNC Hub – ST Connectors
VES 8034/SMA
. . . . . . . . . . . . . . Fibre Optic / AUI / BNC Hub – SMA Connectors

VolAmp Ltd
Unit 3, Riverside Business Park, Dogflud Way, Farnham, Surrey, GU9 7SS
Tel 01252 724055 Fax 01252 733425 E-mail:
info@volamp.com