VolAmp Ltd VES 8044 Hub  VolAmp Ltd

 

VES 8044 
8 PORT 
BNC/1 X AUI  
   

FEATURES :

  • 8 BNC ports
  • 1 AUI port
  • Local and remote management
  • Expandable to 96 ports
  • No single point of failure on expandable hub.

TECHNICAL DESCRIPTION :

Local management is provided on the front panel to provide an eight channel display of link status plus AUI status. The link display is : Port activity -----Port Partition status.
In addition ports can be forced into partition mode to disable unused or problem links.

The VES 8044 provides a repeater function and conforms to the requirements of IEEE 802.3 repeaters:
Fragment extension , Preamble reconstitution
Data retiming
Partition recovery on segment fault correction
Auto – partitioning on segment fault.

Upto 12 VES 8044’s can be connected together by an external cable bus, to make a ninety six port hub which only has a repeater count of one. Other of the VES 8040 series multiport repeaters can be combined with the VES 8044 on the bus e.g. VES 8040 8 port UTP Hub & VES 8042 Fibre 8 port repeater.

Each unit is allocated an address set up by the panel switches. This and all other status information is held in non volatile store.

SPECIFICATION :

Electrical :- Power inlet - IEC 320 Mains 198 – 264 VAC for 50 – 60 Hz at 10 VA Fuse protection: 125mA
Mechanical case :-
Totally enclosed metal construction

Signal connections :- 1x 15 way D-connector (AUI) 8 x BNC connectors
(Channel 1-7 internally terminated )
(Channel 8 not terminated internally or earthed through unit)
Indicators :-.
Collision , Management Address
For each port :- Packet Activity , Partition Status
Environment :- Operating temperature: 0oC to 45oC , Storage temperature: -20oC to 70oC
Humidity :- 10% to 90% non-condensing
Dimensions :- 245mm x 168.5mm x 40mm (body) 245mm x 185mm x 46mm (overall)
Weight :- 1.375kg

VolAmp Ltd
     Unit 3, Riverside Business Park, Dogflud Way, Farnham, Surrey, GU9 7SS
     Tel 01252 724055 Fax 01252 733425 E-mail: info@volamp.com