LS
FIBRE
OPTIC LINE DRIVER
FEATURES:
TECHNICAL DESCRIPTION:
The Model LS Fibre Optic Line Drivers are used in pairs to
extend RS232 links via a duplex fibre optic cable. A line Driver is used at
each end of the link. The link length can be 1km or longer.
The LineDrivers can be used to extend RS232 links further than
can be achieved with copper conductors and provide data security from both tampering,
RFI emission, environmental noise and earth loops.
Pressed steel casings are used to reduce RFI interference effects to the Line
Driver and it's own EMC emissions.
The Line Drivers are full duplex for asynchronous communication
from DC to 19.2kbaud data rate.
They will operate with fibre sizes from 50/125um to 200-380um without adjustment.
The Line Driver can be powered from one of three sources.
Host:- Takes
power from the Tx host line
Power
Jack Socket:- External regulated power supply
Pin 9 of the
D connector:- If this is available on host
Internal jumpers allow the unit to be configured as DTE or DCE.
The unit needs a minimum of three wire connections.- Tx, Rx and signal ground.(Pins
2,3 &7)
Other control lines are internally looped back with connections
between Pins 4-5 & 6-8-20 on the standard unit.
Options are available for other connections and a false control line which can
be used for DSR log-off.
The standard unit has "light-on" the fibre link when no data is flowing.
This feature when combined with DSR log-off provides a secure tamper proof link.
SPECIFICATION:
|
Optical Sensitivity: |
100nW(-40dBm) 4uW into 62.5/125 um fibre (-24dBm) 12uW into 62.5/125um fibre (-19dBm) |
Environmental: Operating Temperature 0oC to 55oC Storage Temperature -25oC to 70oC Humidity: 10% to 90% non condensing |
|
|
Power Budget 50um Fibre |
(62.5um fibre) 12dB |
Signal Connections: |
|
|
Wavelength: |
830um |
Mechanical: |
For user manual click HERE
Ordering Information
LSX-0Z/SM . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..LS
Line Driver - SMA connectors
LSX-0Z/ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..LS
Line Driver - ST connectors
PC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ..Power cube single
PC4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ..Power cube, four
PC8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ..Power cube, eight
Where X indicates, P-Male/Plug, F-Female/Socket
Where Z indicates options; 2- Pins 4,5 & Pins 6,8,20
linked
5-
Pins 4,5 linked Pin 6 - false control line
VolAmp
Ltd
Unit 3, Riverside Business Park, Dogflud Way, Farnham, Surrey, GU9 7SS
Tel 01252 724055 Fax 01252 733425 E-mail: info@volamp.com
www.volamp.com