SYSTEM LUX-10n

Manual

Thank you for buying SYSTEM LUX-10n. This switched hub is ready to plug in and go. Just connect to a suitable power source, attach your ethernet devices to the appropriate ports, and the unit is ready for action.

Supplied with the unit is a 2 meter mains lead, fitted with an IEC socket at one end and a standard British mains plug at the other end. Simply connect this lead to the IEC mains inlet on the rear of the SYSTEM LUX-10n , and the other end to a suitable power source ( 85 -264Vac) and the unit is powered up. This is indicated by the sound of the fan on the rear panel.

The SYSTEM LUX-10n has been supplied to you built to your specification, with the appropriate modules already fitted. For your reference, module options are as follows : -

VES M10/ST       (10Mbps F/O ST connectors)
VES M100/ST     (100Mbps F/O ST connectors)
VES M100/SC     (100Mbps F/O SC connector)
VES M1               (10/100Mbps Single STP RJ45 connector)
VES M4               (10/100Mbps Quad STP RJ45 connector)

MODULE FUNCTIONS


VES M10/ST     }     Link      Green LED             ON, for good fibre Rx connection.
VES M100/ST   }     Rx         Red LED                ON, for module receiving data packet/s.
VES M100/SC   }     Ports     Rx and Tx               Connect fibre here.
                                 
            Switch    Duplex Mode          Left = Full , Right = Half

VES M1                     Link       Green LED            ON, for good copper link.
                                   Rx          Red LED               ON, for module receiving data packet/s.
                                   Port       RJ45                       Connect RJ45 plug here.(Auto-negotiating)

VES M4                   Link        Green LED            ON, for good copper link.
                                 Rx          Red LED               ON, for module receiving data packet/s.
                                 Port        RJ45                      Connect RJ45 plug here.
(Auto-negotiating)

For your convenience module functions for the VES M4 are indicated on the module label, and for the other modules, where space has not allowed, on the rear panel of the SYSTEM LUX-10n.

IMPORTANT INSTALLATION NOTE

When a port is connected, the switch recognizes that address specific to that port. If the connection is changed to another port, the switch will not output to the new port until it is 'aged out', or until it receives an input on that port, and hence recognizes the change of port. The effect of this is, that until the above process happens, the port will not be connected. If power is removed from the SYSTEM LUX-10n all addresses are re-learnt.

 

 

VolAmp Ltd
Unit 3, Riverside Business Park, Dogflud Way, Farnham, Surrey, GU9 7SS
Tel 01252 724055 Fax 01252 733425 E-mail: info@volamp.com
www.volamp.com