STAX 12 F
MODULAR FIBRE MULTIPORT FL REPEATER
( Obsolete )
FEATURES :
TECHNICAL DESCRIPTION :
The STAX 12F system
can be used to construct hubs from 1 to 96 ports with a repeater count of 1.
The user may add ports as this system increases or by having redundancy in the
base unit and modules. A system with very low down time is achievable. The STAX
12F system comprises a 19" 1U rack base into which are plugged individual
fibre modules. Base units maybe chained together by a simple ribbon interconnection
cable.
Each port has a display of LINK, Rx Data, Collision and partition for system
fault diagnosis.
SPECIFICATION :
Optical :-
Max
input -12dBm (63uW)
Min
input -32.5dBm
Max output -12dBm
Min output- 20dBm
AUI :- Socket conforms to IEEE 802.3
Expansion : A 10 way ribbon cable is used to connect units.
Two 10 way plugs are at rear
of unit.
Up to 8 may be stacked.
Controls:- 2 switches on rear for expansion termination.
In any stack a switch must be set on at the physical ends of the stack. Both
switches to be on in a single unit.
Indicators:- Each channel has an associated set of 4 LED
indicators:
LINK -Red on warning link
failed
DATA -Flash per data packet
PARTITION -Off if partitioned
COLLISION -Flash per collision
Power :- Universal Mains 85 -265 v Ac 15 Watts
Environment :- Operating 0 -55oC , Storage -25 to 70 óC ,
Humidity 10 -90% non condensing
Size :- Height 44 mm, Width 432 mm, Depth 180 mm.


Order
Code .
Description
.
Stax F Case . . . . . . . . . . . .
. . . . . . . . . . Base Unit
Stax Mod . . . . . . . . . . . . . . . . . . . . . . . . .
Fibre Module
Stax Link . . . . . . . . . . . . . . . . . . . . . . . . .
Expansion Cable
For manual please click HERE
VolAmp
Ltd
Unit 3, Riverside Business Park, Dogflud Way, Farnham, Surrey, GU9 7SS
Tel 01252 724055 Fax 01252 733425 E-mail: info@volamp.com